No backstabbing for me. I'm on an electrical forum that is of the opinion people who backstab their electrical are pure money making 15 minute service calls. All my connections are wrapped on the side terminals.
After replacing all of them I used an extension cord and metered the grounds and have continuity on all.





Here is a beauty from a local church.

View attachment 194348
Somebody was hitting the communion wine before they put in those switches.
 

Snattlerake

Conservitum Americum
Special Hen
Joined
Jan 19, 2019
Messages
20,444
Reaction score
31,730
Location
OKC
Did your church use a repeatable licensed contractor?

You mean reputable? Matter of opinion there. It was under construction and I had the fire/burg alarm and camera job. This was the same place where I was working up in the ceiling and burned my arm on the 4 inch conduit mains feeding the transformer in the electrical room. It was that hot because of an imbalance of some kind. The city inspector said if I had not burned my arm it probably would have gone unnoticed and caused a major fire. It wasn't glowing hot yet but it was around 150 degrees and the cables around it were warm.
 

RickN

Eye Bleach Salesman
Supporting Member
Special Hen Supporter
Joined
Sep 7, 2009
Messages
25,336
Reaction score
34,090
Location
Edmond
My house was previously owned by an electrician that owned his own business. I have cussed this dude more than a few times over the last 5 years. There is no way half the dova I have found he did would pass code. If you google cheap bastard. Wikipedia has a picture of him.


To be fair, many people in the trades are the worst about upkeep on their own home because they are tired of doing it all day. An electrician will only do what he has to keep power, plumber water, etc, etc. I have seen it many times.
 

Snattlerake

Conservitum Americum
Special Hen
Joined
Jan 19, 2019
Messages
20,444
Reaction score
31,730
Location
OKC
Were - low voltage tech yes.
Larm guy yes
I was installing a camera up in the ceiling while the electrical inspector was doing an inspection. After I burned my arm, I brought it to the attention of the EC not the inspector. The EC put a man on it right away checking the problem and discovered the imbalance. That is what they told me.
 

EKing

Sharpshooter
Supporting Member
Special Hen Supporter
Joined
Jan 21, 2018
Messages
401
Reaction score
480
Location
Harrah
The security and fire alarm guys crack me up. They run their cables across the overhead any way they see fit but us data/network guys have to follow a standard. We'll get in there and see alarm cables laying across the drop ceiling, draped on sprinkler pipes but we have to make a proper path with J-hooks.
 

SoonerP226

Sharpshooter
Special Hen
Joined
Jan 1, 2013
Messages
13,434
Reaction score
13,851
Location
Norman
I used to know a couple of staff electricians at OU, and they had some stories to tell. Let's just say that electrical codes have changed a mite in the 100+ years since some of those buildings were built (and electrified), and not all electrical contractors do everything according to Hoyle.
 